https://3dfs.com/innovation/features#ZERONL   This article on Zero the 
neutral line reminded me of the numerous articles from up in Wisconsin 
dairy country where remote farms had dairy cattle electrocute in the 
fields and people drawing sparks at the kitchen sink from the faucets!  
True stories. It all had to do with neutral current flow back to the 
power generating station through the ground.

http://www2.uwstout.edu/content/lib/thesis/2000/2000nackersm.pdf

https://accel.wisconsinpublicservice.com/business/farm_voltage/electricity.aspx


On 7/31/2018 10:49 AM, Norman Wootan wrote:
>
> http://videos.mathtutordvd.com/detail/videos/ac-circuit-analysis---vol-4---3-phase-circuits-part-1/video/310jd_DxH2s/01---what-is-3-phase-power-three-phase-electricity-tutorial?autoStart=true&gclid=CjwKCAjwkYDbBRB6EiwAR0T_-vs_AKjNp0I0qqXru1Qxt-eF716Y9FgaW8Gah3w0eq3vgop_UD-oZRoCAHYQAvD_BwE 
> Please!  Some of you need to go back to 3 phase power 101 just as I 
> had to do back 35 tears ago when I started working with 3 phase 480V 
> buss power.  The holding Co. that  I worked for had 14 Commercial 
> properties with all sorts of power distribution. My favorite property 
> had a Trane Centrifugal (300HP) compressor in the chilled water 
> cooling system.  Back in the day that this system was installed, all 
> that was available for phase imbalance was the old Furnas magnetic 
> sensors. If an in-balance in current draw on a motor leg (over-voltage 
> on a leg) occurred it would trip out the motor contactor.  In summer 
> with heavily loaded power  grid we had frequent trip out on the 300HP 
> motor controller.   TU Electric brought in and analyzed the incoming 
> 13.5KV to the underground transformer vault. The analyzer was left on 
> incoming line for several days to get a plot of the power quality. It 
> was found that during the day some load imbalance between 3 phase legs 
> (13.5KV) gave voltage excursions which caused our problems. At the 
> power sub station, more capacitors were installed to bring power 
> factor back to optimum on all three legs. Problem solved.  As time 
> passed, companies like Fluke,Drantz and others came up with power 
> analyzers that were technician friendly and were hand held to look for 
> these problems and harmonic distortion in your power.  Later more 
> companies brought onto the scene solid state devices to monitor power 
> quality directly on your application such as large elevator motors 
> (30-40HP 3 phase) . The point here is that as we have advanced and 
> have better understanding of power distribution problems, Industry has 
> kept pace and have given us the means and methods we need.   All that 
> you seek to track, capture and put into useful work is right at you 
> finger tips. It is just your desire and ingenuity to apply what is 
> known to accomplish your goal.    I guess the old military rule should 
> apply, KEEP IT SIMPLE STUPID.  The old KISS rule.   Stick with 
> thyratron tubes for final control or switching for solid state is 
> cannon fodder to spike energy.  Just my opinion!  Thanks Norm
>
> https://3dfs.com/articles/automatically-balancing-phases-in-ac-electrical-networks/02/2016 
> Now let us look at Neutral Current!
>
>
> On 7/31/2018 7:40 AM, Norman Wootan wrote:
>>
>> Doug & Warren, I love your thinking process for designing a circuit 
>> (Ardino ?)  that rapidly tracks the capacitance values needed to zero 
>> in on the targeted frequency for hard ferroresonance.  Since solid 
>> state will not survive the environment, just use the circuits to 
>> control hard tubes like the thyratron do do the heavy lifting.  Auto 
>> tracking circuits can be made to mitigate (avoid) the ferroresonance 
>> phenomenon, therefore the same circuit can auto target the values 
>> needed to capture the circuit parameters needed.  Just my two cents 
>> thrown in, soon we will have a whole $dollar!  Lol   PS: Doug, I like 
>> the Fuck it, just Short Circuit!   On my 5 HP compressor locked rotor 
>> experiment, I used a simple overload relay which was set for drop out 
>> at locked rotor amps (82 amps) which gave me the super saturation of 
>> the motor iron when the 2 pole single phase contactor (230 VAC) 
>> opened thus leaving the whole shebang in an isolated condition (no 
>> ground reference). When the isolated energy (magnetic saturated iron 
>> and 45mfd caps) cancelled, I got the EMP shot in the earth ground, 
>> Neutral Spike.   Your thinking is right on!   Norm
>>
>>
>> On 7/31/2018 6:22 AM, Warren Keillor [email protected] 
>> [EVGRAY] wrote:
>>>
>>>
>>> Doug
>>>
>>> What is the cheapest, simplest, detector for peak voltage?
>>> With such a detector, the signal can then close a heavy duty switch.
>>> If it can chase the sine wave, where ever it goes, then you should 
>>> be able to harvest the maximum energy.
>>> Detectors: we should make a list of every possible peak since wave 
>>> detector, for consideration.
>>> Switches: relays, electronic, and mechanical methods of closing the 
>>> circuit at the peak of the since wave, should be also listed.
>>> This energy works. We know it is there. It burns out brushes, and 
>>> commutators, and heats up power tools.
>>> We also know we can bleed it off with diodes, to use in yet another 
>>> motor, and actually see the voltage increase, from one motor to 
>>> another, with permanent magnet DC motors.
>>> The beauty of a solid state transformer based device, is that there 
>>> are no friction producing parts rubbing together, turning to powder 
>>> as it runs.
>>> Cheers Warren
>>> Sent from Yahoo Mail on Android 
>>> <https://go.onelink.me/107872968?pid=InProduct&c=Global_Internal_YGrowth_AndroidEmailSig__AndroidUsers&af_wl=ym&af_sub1=Internal&af_sub2=Global_YGrowth&af_sub3=EmailSignature>
>>>
>>>     On Tue, 31 Jul 2018 at 12:42 AM, [email protected] [EVGRAY]
>>>     <[email protected]> wrote:
>>>
>>>     Hi Warren
>>>     Just my two pcents but the variables to create ferroresonance
>>>     and also resonance let's say in Air coil too, seen to be
>>>     frequency, capacitance and inductance....however perhaps there
>>>     is the fourth dimension overlooked which is extraction of this
>>>     energy, not just the observation or prediction of it or the
>>>     cancelling or avoidance of it which usually seems to be the
>>>     "scientific purpose".....
>>>     As Sven is doing with diode plug exprimemts too,, he is
>>>     extracting it into a load ( and not direct lump resistance.load
>>>     as is shown in figure drawings)
>>>     And so the distribution of the positive or negative energies in
>>>     sinewave via running through diodes into what I call collector
>>>     caps, .
>>>     and only the collector caps see or feel effects of resistive
>>>     load (and only discharged to resistive load when isolated and
>>>     independent and disconnected more or less from the system or
>>>     circuit that filled these caps)
>>>     now this brings upon not only the fourth dimension of "means of
>>>     extraction" from the "resonant collecting caps" but also there
>>>     becomes the fifth dimension of time and timing of how long and
>>>     when to fill and discharge the resonant collector caps
>>>     Also as caps fill over time, and when they discharge and refill
>>>     they again change the ferroresonance or resonance "parameters"
>>>     of primary system that fills caps.
>>>     My sick plan is to fuck it all, instead SHORT CICUIT
>>>     inductorsvery briefly with switch at peak periods, this cause
>>>     hypernringing within coil and gives you simulation of resonant
>>>     condition since you have same effects you want in extraction and
>>>     that is voltage increase into capacitors X 20 or X 50 in magnitude.
>>>     Also short can be applied to AC or DC impulse take your
>>>     pick...with DC it is done just before saturation, with AC,
>>>     at.voltage peak periods.
>>>     Kone
>>>
>>> 
>>
>

References

<[email protected]>
<[email protected]>
<[email protected]>
<trinity-a2ab2c4d-4bea-40f2-a7c6-0d308c871aba-1532947811591@3c-app-gmx-bs15>
<[email protected]>
<[email protected]>
<[email protected]>
<[email protected]>
<[email protected]>
<[email protected]>
<[email protected]>
<[email protected]>
<[email protected]>
<[email protected]>

Headers

Return-Path <[email protected]>
X-Sender [email protected]
X-Apparently-To [email protected]
X-Received (qmail 26544 invoked by uid 102); 31 Jul 2018 16:15:35 -0000
X-Received from unknown (HELO mtaq4.grp.bf1.yahoo.com) (10.196.227.14) by m4.grp.bf1.yahoo.com with SMTP; 31 Jul 2018 16:15:35 -0000
X-Received (qmail 28336 invoked from network); 31 Jul 2018 16:15:35 -0000
X-Received from unknown (HELO mta4000.groups.mail.ne1.yahoo.com) (10.222.143.200) by mtaq4.grp.bf1.yahoo.com with SMTP; 31 Jul 2018 16:15:35 -0000
X-Original-Return-Path <[email protected]>
X-Received-SPF none (domain of att.net does not designate permitted sender hosts)
X-YMailISG sNrnH4wWLDss3zlmxSRXVplG1puchXXnrU2wDi4gct9QY2FD .9L6k1p6o4bDPZw9K1H9xKCiZw8faMZkLJy6ChzHOR8_YgRnVuIEoeBq0ao6 DmSE5pPTevMXWpBuSxMcvN1.FrURd34fL1a0GTr84Csmpx6JedruP8sJx1Qs 4b4cDcWEDRv.Qh34UH2s4rxCkXDBctN090G.of7PdLGmEj4hcdFL2.XpFPyg OeW4AAexhxDGWQwWnFYjXv.iZ4bRx4UYmYFJFIbSnXJB3Ll4ApXKasJw2ky0 NxZ329Z8Sngn1mFKLWR6RvvDFlqhURTOZUt65OOOxUcdQ_Wh6l.qY6RdjdXI aC4afHsAiu15ZSpEj4RkDXLe9Yz91Pfqvhs0zPJknZH5TCEeCXny4FMltsPp Oz1vrmvrMctqjq5el_XDh4RfCww10Ew6CJ7PwNOQLlp7auOVgRB1tq8hRVfJ 1vrreh7BGK4dU_WGNNT7VCtXUrTDrJ3v7639NcXs6hK1Zsq82IOwhCpDFkGU QuecWSW7hA0OcIgLGs1T1c0IHhrcbbb3luJCHFQVJ5yDdJQPgBXMyqBiFIYB gGzbWLkQLmaO41c4D_b0vY0.WDSKW1wDJeB5_MJ0KHR2gfSo5_AIqb.V8w6C pleWtSBg9.RUPAgcLDLIJZcdezxGtEh1uH78eVGUpxjZK.wgHfco_vcCGgYQ DV4nXemoW_F8Lah0YDtGE3uE1.YEZ8ennCYfYyeyT5UrhjbOaTk2ib5TGZHp vlEYo3CodilPq5rMLAzKgQ5yQTvhHh2G0BNq1Mf1zontppcAnN3co4COt.Yn gE0jFU3XHy8f9_kDBO6nd4rPKqCrO18mkMNV3eIpEjocE0Pg_e0di9Zsu2Rx 3dBAb4hM.PdNYa_XVmwIDjC0ozg9SWrgY6DiVEQkkygEavdjfoTbs5E9DP5X grSZ6IRO6hyH96jxqol4tj1CTpfdUrp1P8Ll1DkTbiuTEU0LSwgJxMuxdx9F N.6ZnDxtLVhull64ywZgYGUO.uRYUdcRADWWWqmmidRGV3QTXzUz7STXCYVh QKDa26hP5cyMlbRVZl.J.kIeUZfiHNvf9LxhO10I3OtpX1cTHaVjg_lpjE.I Rwds6ZKlPkatSsVP97ifaEBh5kjb_0VudurrEmWgnco7oz_VFg4zDTBg5uN2 9x4ch3n10YmU.oSSasK9HfPFCZI8pqZPpV9Fp4QnKbPmkCv4w8Jh2zjfdOFb y.l0TO2zjN5sVoCTDhJgBXmqYcDExpzbN2wlAWFNw6asC8HZCXBvXHAczC68 guN5vxtkoxbiDpJAKuLFt7BKIoZiXlGHj7PWslXzGVD1nD6jMCJ7F8oysGLp m6wrOOM2xb.Tx6WluAW229QxLigDyO9wxK6.0HTk8H0vy.zo70eKRoB.2HL1 8k2ng6jHUi_33pH0sYYwTRdRMTGPzs_fKcojuWa.Txyzx5MjbgLYftDFx6fs xickVJH_cmrizDtDejzwRSbI5aWU559F7vP_DOVOhC7sCMFG6HuI29DDKYeh kZ5wQ2LbT5_zndOuteBSNg--
Authentication-Results mta4000.groups.mail.ne1.yahoo.com from=att.net; domainkeys=neutral (no sig); from=att.net; dkim=pass (ok)
X-Received from 127.0.0.1 (EHLO sonic311-25.consmr.mail.gq1.yahoo.com) (98.137.65.206) by mta4000.groups.mail.ne1.yahoo.com with SMTPS; Tue, 31 Jul 2018 16:15:34 +0000
X-YMail-OSG tsHSfogVM1nldy.EW1H9CQx.r96jcdgBH8mKoVOGLOazaGgAE9tto64hvdkheBH vr7kCmuYgGacHcj2V37huS9M.hwvKkdcKl2x_oDNlxE_ibQ44ME7FDlcUddL5GnrRap6Fm18tcDD YRRdJId1iK2n3DHHk22hKfbWADzmhrCn_dA4lM3HVuu.wqgZRVgVxQnw.WNltuYKeiveYIpsxS5i _HtFwO2zPq_yoagoWN.uv4Hl5JAQoClbEtTcs6hnsLjxF_CiSqyyMqSZIpUimk2ARVx02Hj6fl6Y 35hIvNEm1N_GAelBwCNwoAjqZURpHdp3kTGXquyaw6GUYsy0rtfNXnjXtSqqCwJoNC3Yh2M13ZA. Jk1tYyy.QJB.78C6WU0RPi5dfoU4s2IE2X5_FA3FBIRmoGp3gv5dm0eIGsLash7vBkSLBk2DeqDP KM5vw3wxm2nFyPfJD5oTl5V2NzcdLyjqNy8.tnBAHCuJxRS9KCFOq.eHktyCBqDnVWqA3FSAYe6u RIpXGfdlnHyXMtr9MtIVNTVd0kVe_EsAZrfrNbFY1FJKtqeArFxRVyTrtq76mFnOS6dxfH08tQGl Ceqrm904is5ah5QUlVLp3YfMGKb89.FCTsssPYbubF776uHYYMcGclY7LD1jLD1gMCnBePey3UCD 824P4UB1y0JYEb5V0t6rAlM9JYj.6hh3bDFoOV.wAtHEOViGBQCJiSwXkTwKVhZLdNzAgNMX3_w. nOmrucgnoc4wcw6aR9dK7078.JrfQz153t50ThRaoh5NAnraTtlhQzsJVfBxtEtYCgtb9D6Tggnr 2RIvBzGoKjYG3CARajCUGstWCyOlgQT1qQ.6tEul4nNfNuU_mcSKVCRfwxuECUaVWLeZFOfKVeVO SxPcgabjQ9CYSUOkh6CE5uTlkByzMUrk0UTiIF.B_fQkRXlnEDtXo7JrUZILsTx3KFZhvkwoc.Rd 7ng307KxVFfPthtITBYAKHhAJmSYzWAs3gGdmhgg2a4ivAUkz_.P1SJ1JsAciXmDBq9.P
X-Received from sonic.gate.mail.ne1.yahoo.com by sonic311.consmr.mail.gq1.yahoo.com with HTTP; Tue, 31 Jul 2018 16:15:33 +0000
X-Received from ip70-189-9-73.lf.br.cox.net (EHLO [192.168.0.4]) ([70.189.9.73]) by smtp416.mail.gq1.yahoo.com (Oath Hermes SMTP Server) with ESMTPA ID 2ab88dcb072402319f9a0b20d1b3adee for <[email protected]>; Tue, 31 Jul 2018 16:15:30 +0000 (UTC)
To [email protected]
References <[email protected]> <[email protected]> <[email protected]> <trinity-a2ab2c4d-4bea-40f2-a7c6-0d308c871aba-1532947811591@3c-app-gmx-bs15> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]>
Message-ID <[email protected]>
Date Tue, 31 Jul 2018 11:15:30 -0500
User-Agent Mozilla/5.0 (Windows NT 10.0; WOW64; rv:52.0) Gecko/20100101 Thunderbird/52.9.1
MIME-Version 1.0
In-Reply-To <[email protected]>
Content-Type multipart/alternative; boundary="------------A3A5FC21B8D2F41CF1DF184F"
Content-Language en-US
X-Originating-IP 10.222.143.200
Subject Re: Aw: Re: AW: Re: [EVGRAY] Low Lenz in plain sight
X-Yahoo-Group-Post member; u=554418533; y=lN7xV3oCEant5OnJKfX5L5C8q_JVUBVATZXy2woAZQnBgEEEtJeSNHkN
X-Yahoo-Profile [email protected]
From Norman Wootan <[email protected]>