Hi Sven,

"Of course I have to split the lines through the capacitor bank with the switches so that I can switch several capacitors in parallel. Can the switch contacts of the switches cause this difference. Or is it due to the cable length at the transverter. I have these differences without diode plug or other observed and measured."
I've been looking for your schematic. If it's still like this pasted one the positive and negative sides don't trig at the same voltage. To be able to do that the triggering circuits of each side have to see the same potential. The tolerances of the capacitors can also be the problem. If switching place of the capacitors also shifts the asymmetry it is because the capacitors aren't of the same value.

The left hand side has the filter resistor go to the anode of the thyristor. The right hand side has its filter resistor go to the opposite pole of the main capacitor and thus only see the voltage across that capacitor. The left side ought to be coupled that same way for symmetry. I.e. move the 1k resistor to the other side of the primary winding to connect the triggering input directly across the left side 15uF capacitor.

Regards
Ole 

---In [email protected], <s.friedrich@...> wrote :

 Hi Ole,

that is not so much, the incandescent lamp with 116 watts light up slightly with a 400 watts load on the secondary side, at 1200 watts load with a 3x 400 watt incandescent bulbs the 116W incandescent light only slightly, so you can once again shorten the switching times minimal perhaps If necessary, install a small capacitor and the light bulb parallel to it. It is signaled anyway how the impedance behaves, a great indicator. The thyristors switch off really fast, the actual 5 milli seconds I have to unload is not nearly needed. I think that with me the synchrony of the components and the length of the lines is a problem.

I recently connected the rotating iron meters for electricity differently or took the other line to the capacitor bank and measured slightly less current there than in the other current path.

The problem of how should I change that apparently does not flow everywhere at the reactive power the same electrical currents.

Of course I have to split the lines through the capacitor bank with the switches so that I can switch several capacitors in parallel. Can the switch contacts of the switches cause this difference. Or is it due to the cable length at the transverter. I have these differences without diode plug or other observed and measured.

regards

Sven

References

<[email protected]>
<[email protected]>
<trinity-6a9ea946-1996-4824-898a-d74a39cbc01e-1519935217265@3c-app-gmx-bs51>
<[email protected]>
<trinity-c90b9955-6924-49f9-b7da-98c9094a3158-1520177723083@3c-app-gmx-bs73>
<[email protected]>
<trinity-968aca7b-8397-494d-b8e2-30fbc7f5f922-1520180355011@3c-app-gmx-bs73>
<[email protected]>
<[email protected]>

Headers

Return-Path <[email protected]>
X-Sender [email protected]
X-Apparently-To [email protected]
X-Received (qmail 1220 invoked by uid 102); 4 Mar 2018 21:55:04 -0000
X-Received from unknown (HELO mtaq2.grp.bf1.yahoo.com) (10.193.84.33) by m9.grp.bf1.yahoo.com with SMTP; 4 Mar 2018 21:55:04 -0000
X-Received (qmail 3509 invoked from network); 4 Mar 2018 21:55:03 -0000
X-Received from unknown (HELO mta1004.groups.mail.ne1.yahoo.com) (98.138.100.119) by mtaq2.grp.bf1.yahoo.com with SMTP; 4 Mar 2018 21:55:03 -0000
X-Original-Return-Path <[email protected]>
X-Received-SPF pass (domain of yahoogroups.com designates 66.163.184.89 as permitted sender)
X-YMailISG NEKKMLwWLDvXqr8Mk_CHDGeLNcGWiTZuHBpgdkLlamUgmM8C Nz8NA0AAgxRTlv9Xmldot4My_Ef3_ZPqqmi8UPWGrCvHbJ94e6A..fPzih.l Y_8JFLPOiywACT93lxIRxtrfP_A4vg9Q4E1g61rKACx4xXIhKX9RdypKRIwk 2WJsuh3o.__BzSHafPc7gNHyAODdnYFVutdDnM1ewnG07kwv4JtdugAD.h0v WXlmYBs_cP0vKD6DqdeS8lXzgK7IgfuHRBXMIG18pCxk04AuZywbSr9Gmdal 2pv9vKoexwfk2hdLoSFQ.mbp.TaqdJ2NtArzKKBjvYpFXqjgvH3pSqYoU7f0 IxB6sZ1KlwRb5aNsnZsbL_qN.9tXaLj1pMRfO2Pl0e_CLmqplp4ygOH2kTbx Xs7aVDy_PzswkwKDQFBzO2U3jkKnghnuWyzKjrhP4lrnAz7Nlnr4bxazN8yY qZrEVvzYVj4A6vbLSnNVcR19j4iBN9yxTEHjw4PvVB_NULMWdtJ2Hg_lb3yL O.zt84W48wSs7Dh7UEf8FAMnHkWlb7kUo2AOnwXqbHJGfzJuuvDkW.28aCKH qHEgH37bstpViW7RYKLXwmLMuQ5hQrN3oeuDQtR0lLaHZxNak7hMyZgmi5wn T45XLqnESkuuQ9Nh3KI3hncmtSsLTBEU_PqDhqfwKks1j178SJVwf5fuNmld xd9wKYAyrpca9hROZWjN4PL6rDgJUt1NawFrK.Oo8GUAK4xqlD6UhpGjAG1F BlKJc15ytKgPTji_V.5ta.aLRjUV6I_sMKUJEASvvztleGn_PdGdPG5SL1Zt ERQeWkNnISyHbv.3FtgofPIkFuNRUugqxUOVwG1clzqZcnOWvbd7VsUoETT8 f9Dllg_IfKGSGMHYikHlpdRgTRxyFkiFLl3CutSCUULEyI1i06KTX120I31R yeVzSFbW0iBZHqg8l9giy4_SqHIPmfP261IEpsGkTZm8vSchFJsGIoDclj7g Us.EtIPlWpyS.di_xrkM8jvAVJladTbz1uY6waHufyPQRYB22QuVPoIt88_c vwQ1HWjEgclWLeWcH6ryIyyHjLhWkpj3pVING_5ZyKAcgBm4wKTJgKonR1RZ UAjm2TPjriFzQJSPZBs4GdyfNpp9JGEFkCL4jIgYFpnbpXruNmqz1yV553W4
Authentication-Results mta1004.groups.mail.ne1.yahoo.com from=yahoogroups.com; domainkeys=neutral (no sig); from=yahoogroups.com; dkim=permerror (bad sig)
X-Received from 127.0.0.1 (EHLO sonic325-29.consmr.mail.ne1.yahoo.com) (66.163.184.89) by mta1004.groups.mail.ne1.yahoo.com with SMTPS; Sun, 04 Mar 2018 21:55:03 +0000
X-Received from sonic.gate.mail.ne1.yahoo.com by sonic325.consmr.mail.ne1.yahoo.com with HTTP; Sun, 4 Mar 2018 21:55:01 +0000
Date Sun, 04 Mar 2018 21:53:17 +0000
X-Received from [127.0.0.1] by gapi8.grp.bf1.yahoo.com with NNFMP; 04 Mar 2018 21:53:17 -0000
To [email protected]
X-Original-Return-Path [email protected]
X-Original-From [email protected]
X-Mailer Yahoo Groups Message Poster
References <[email protected]> <[email protected]> <trinity-6a9ea946-1996-4824-898a-d74a39cbc01e-1519935217265@3c-app-gmx-bs51> <[email protected]> <trinity-c90b9955-6924-49f9-b7da-98c9094a3158-1520177723083@3c-app-gmx-bs73> <[email protected]> <trinity-968aca7b-8397-494d-b8e2-30fbc7f5f922-1520180355011@3c-app-gmx-bs73> <[email protected]> <[email protected]>
X-Yahoo-Newman-Property groups-compose
Message-ID <[email protected]>
In-Reply-To <[email protected]>
MIME-Version 1.0
Content-Type multipart/alternative; boundary="9nlWnTS9ocNmxdhsK3FKVLWiM6a5jwOaA8HvrLV"
X-Originating-IP 85.81.0.233
X-Yahoo-Post-IP 85.81.0.233
Reply-To [email protected]
Subject Re: Aw: Re: Re: Re: AW: [EVGRAY] Re: "Impressive"!
X-Yahoo-Group-Post member; u=115023864; y=PnJY_FmIn0zUzQutVzuAhYcmdiGiTT21DDsquf71L8GX9kNsjIqh
X-Yahoo-Profile onielsen2000
From [email protected]