Hi Gerry, I have extended the shunt a long time ago from a defective 30kw danfoss inverter. I used that for it. Of course it will be more difficult for the scope to measure the low voltage drop. I have grounding points only through the new scope. By the upstream isolating transformer I work earth Potential free if I understand correctly what you mean!?!. The cables are all designed in 6 mm2. I have set up the resonant circuit freely switchable so I can always other components such as transformers, etc. intervene therefore the clamping rails. About a 3-phase 63A switch, I can close the resonant circuit all-pole. Greetings Sven

Von Samsung Mobile gesendet

-------- Ursprüngliche Nachricht --------
Von: "Gerry [email protected] [EVGRAY]" <[email protected]> 
Datum:17.12.2017  23:24  (GMT+01:00) 
An: [email protected] 
Betreff: Re: Re: Re: [EVGRAY] Oscilloscope problematic. 

Wow Sven,
That's a heavy duty shunt you have there!
The big bolts are to carry the large current under test in and out of the resistor via brass blocks on either end.

The two smaller connections are the voltage measuring points, the resistance is correct between these two points.
It is correct to place your measuring device here, but like me & Ole said.... have to pay attention to your earthing points.

I can see a high current connection to the left end but not the right hand end of the shunt? 
Where does this current come out? 

I don't exactly understand your words in your email above "I still need capacitors for the sheath current filter because I lie partially over 600V, or in series...."

Do you mean the whole shunt is floating at 600V above/below  ground potential?

Sorry... me easily confused

Since shunt is intended for up to 200A and you are only using it at 35A the voltage per amp is going to be quite small.
So  noise and contact potential errors may creep in through dissimilar types of metal at junctions.

I do recommend to try a clip on type ammeter or Hall effect probe for these kinds of measurements.
Gerry.

Here is a link to some other shunt resistors also 
https://www.jaycar.com.au/search?text=current+shunt&CSRFToken=0cf93697-a46e-4fc8-ada7-969a3dc631c3



 




On Sun, Dec 17, 2017 at 10:53 PM, 'Sven Friedrich' [email protected] [EVGRAY] <[email protected]> wrote:


Hi Gerry, I measure at this shunt. The small lines that are led out, I connect to my scope..
I think 200A max. rich for my max. 35 amps in transverter reactive.
I still need capacitors for the sheath current filter because I lie partially over 600V, or in series.

regards

Sven
 
Gesendet: Sonntag, 17. Dezember 2017 um 02:31 Uhr
Von: "[email protected] [EVGRAY]" <[email protected]>
An: [email protected]
Betreff: Re: Aw: Re: [EVGRAY] Oscilloscope problematic.
 
Hi Sven,

Sometimes the high current shunts are 4 terminal resistors.
Usually the two larger terminals are for the current in and out connection.
The actual nominal value of resistance is only correct between the voltage terminals.
Which aren't designed to carry large currents.
 
They are also calibrated in so many nominal mV per Amp rather than Ohms.
 Gerry

Headers

Return-Path <[email protected]>
X-Sender [email protected]
X-Apparently-To [email protected]
X-Received (qmail 14036 invoked by uid 102); 18 Dec 2017 07:52:33 -0000
X-Received from unknown (HELO mtaq4.grp.bf1.yahoo.com) (10.193.84.143) by m2.grp.bf1.yahoo.com with SMTP; 18 Dec 2017 07:52:33 -0000
X-Received (qmail 11556 invoked from network); 18 Dec 2017 07:52:33 -0000
X-Received from unknown (HELO mta1006.groups.mail.bf1.yahoo.com) (98.139.245.165) by mtaq4.grp.bf1.yahoo.com with SMTP; 18 Dec 2017 07:52:33 -0000
X-Original-Return-Path <[email protected]>
X-Received-SPF pass (domain of gmx.net designates 212.227.15.18 as permitted sender)
X-YMailISG 2UxHoWsWLDvWuB9XQa137DG91x39rW_GobsG.vqX4L_FJ81Z 50hc1.gaQFp05C2Xbn2Sg19kJ2RdZX5NGNFMGYKGgzmJPLT7L1X5_F7Pe8LQ aNDThpXznu2WlPA1R5MMXBU_czUJsVKQxtcdqZoQKlg_SiZEdnNg7WQWXggK NARcyfgHtJ7JyR_.VYQ52L_mYtvLSYBTNzluDkn4ULzIXep9Gp3Z82Q1Ffh0 ZrRwmwtT6FEfXSYqTarKXyR7SRhmqakOn9YExEpjWwJAsYFaY2yUT4vt3yq2 ZooIvsaEgAlUZ93ECUFNusvc2mGp8vmkr_.trcHx4BWyaWhsT0dtAOZh5mA6 SSmpbCrjLJrquKM6Gu5.s8UDJrFpQmAVh8aJw25HsJnI6ZCjDJ_UeozKYCi3 e3YSOx7WZ_hSYSLO.AI8PfCeCBFCdGJFeaaUP2mn9k0tG0r8AHg51gcvu_.I F21crCSieFpfjiw0jZlHK0k2xOg6CvVxfl1leqBXhGVT4G7z24to6_wJSD6S GAgNllzUEF0cTilv8oc7U1gGEjvTPfgu1q3SzGkKLsKRGAA4acqNtr_EFyTg Sp.KmAh5pOUHtxFNVPrIlZaPq1BpCSmlTCJ3NprgSLLAPxHzkJgS8h.Kq99r X8fXpqnWhJ3EPOj11uIo9QIM6PlfsjgSOjfF1DryvMEtEEnAqfcIGw8crbEq AdQTlOvvUcKUK4FJlKopjsXB89B1OH5jEglb4ZqFJq1PqT4BAn4X_A8qVsLM NzSdwXwOEfiy8GU.7wzNMOJwHp9pVKiOb09sdqrDOc8KIYbErL4ErEKjHhWs X4qonZ5yvTjJ84ehDUJUypUpb4oUozx6hTgLl8mW_JhWB.KBmde1rYoKqDav nVWpycWsSWuQ7Fw1yJwNzCyLYO1YpgZyfu_q2QXT_E_NDbxTxjwQ9HYCn.eB hcBuX2.F.ysjwCrm2ZbUs0uw.499.PN.aBpP06q.HYme2dpRsnqxsQFIuPW8 HuUgZPiYx10l4.CmLP04oQL9_QvxpjGe9h2drSW2LUAV4wdAiITkvXTgwPjs 1Ea1sHhAdM8ktNtY01svK8_Nzvf8GiP3pRayGjNIFt0ehOKLNqjhOS6NjB8D as5TE7dHc4gFCnGhi.U0qkXn5iutAHB4lk.k3DKEPIuJ2N9W3HDF2Ztbw80D yW.1ic1RsMmF.U45a6kTzXl2LohLZWEIxuk4z6h1EJqOhppVBKX2zLLMAFgg pEcON8OiWVBNRqD3NWTWKv95hbPVb2xDOhMCUjoXrQQ.bsKrII09mg4U4H14 p.h9sUVH
Authentication-Results mta1006.groups.mail.bf1.yahoo.com from=gmx.net; domainkeys=neutral (no sig); from=gmx.net; dkim=neutral (no sig)
X-Received from 127.0.0.1 (EHLO mout.gmx.net) (212.227.15.18) by mta1006.groups.mail.bf1.yahoo.com with SMTPS; Mon, 18 Dec 2017 07:52:32 +0000
X-Received from [172.16.2.67] ([185.65.193.230]) by mail.gmx.com (mrgmx003 [212.227.17.190]) with ESMTPSA (Nemesis) id 0M0gcI-1fIGcV20WU-00urZF for <[email protected]>; Mon, 18 Dec 2017 08:52:31 +0100
Date Mon, 18 Dec 2017 08:52:31 +0100
Message-ID <[email protected]>
Importance normal
To [email protected]
MIME-Version 1.0
Content-Type multipart/alternative; boundary="--_com.android.email_13454370322964710"
X-Provags-ID V03:K0:Bm4/DldwdLTJqsqsIQ38R1Xn89Rdld+FvaenU4Y8OBDW71gzaqa GH04ItBz9Q5ismUUABm9kCDhTTEQLpY8LxrvFJsEfn9PTbIRs6Y18ja14bxraVWhhyOWMlu bDYxo+/BDCVHnWHthwIIwaCm0hZn6iXAkxT1TiNwyP0NvloDxk+IflaDir00F0bIR4TAz8G bg9/qeAipyY7E299kEK+g==
X-UI-Out-Filterresults notjunk:1;V01:K0:NjCC9OseWVQ=:PXe7HIXi9YIFIy2aeHcy4W JmSx72/cyxJXTSssvZRwKsxWWLfi6kju+E9oUu4p+iPjkx2ZKBFrCt1O5KpXWbKbrESEfddW5 1Bm0M7xbWL56xLHkepp/uISknginuI0h4Om8YF4Nxe/k3wInig2NX5Vl8Ds9qgiGkvpAyLYaG VddLkW3+rnyMT47XYpyopIrI7/8hrTP6Sl+Gs0MLsYOCEgnBnBTrNu5SU0X93MTQPAco4rMes UkwjsDYyv2s3/ZqX9AmxBeIUsEjKJ3wgw7VQNsRbyaifl+SUNJBt1yk8rNEQz3QCLH4Q3pZYu oNPgTvt3KJL0jgUodicNTugRy8C8Y6W9KC07tHzKdrjvQj+ummM9VSdPKy2yAT5Xd91BRT36i mmtYoggXUg9BdJ2UJBEHxkUyYb+2a81ofR6qOtxGM4j69VosWB3uRZOHyIVuLyPf3kMcK1X6O K29eg4RecWaqfOitLvW/zZhQHH1ow8DNOVJLh8BwfMTU2npPb92FGpREMYTTRZ4z1TU3HC0/X 8oNNtiuBQ4RyoH/NtVRpRbCjajXY1TICm6tsAQOs/KfBZm91lXWeDR9WbY8lIOPR6aPKplHy4 brP2kVDqOumbuAgq0vvDmsS1q/3YDp840Yr9ED5sUkq0bH7sMY69Ett4O/APfDEKxgY/4VcNV 0i+E5v2U7ioZdFvX+12WMj89Lrtz3e51JGxBIqO1hHAkBQLZ03chZQX8Ao9RxELYX5eqloQXX xIOBnn6FQLrKV8KlityBlMTTmTOQa4mwHoDjZmIcxhT5cAnldg2PvtLoFWFIEXyYJ/zmp8lzO YfZpICdw1PBwp6Et0WZOihTry3kSzXVyj9QqS3jUjfGlSVxiro=
X-Originating-IP 98.139.245.165
Subject AW: Re: Re: Re: [EVGRAY] Oscilloscope problematic.
X-Yahoo-Group-Post member; u=562176542; y=JkRl6P74xUX7yiQShUPF5wjlV9E7TnZF3S9K--YQAEN8Ow
X-Yahoo-Profile svenf73
From "S.friedrich" <[email protected]>